User Functions DNI-3 User Manual
4-2
Telect, Inc. 108469 Issue A Rev 2
4. Using a fourth Mini-WECO patch cord:
a. Insert the plug of one end into BOR position 2, OUTPUT.
b. Insert the plug of the other end into the IN TLJ at the first loca-
tion.
5. Insert a Mini-WECO terminating plug into the OUT TLJ at the first
location.
6. Insert a second Mini-WECO terminating plug into the OUT TLJ at
the second location.
OUT-OF-SERVICE PATCHING
To temporarily connect an NE or DCS circuit to an alternate DCS or NE
circuit on the same or a different DNI-3 panel or DSX when service has
been disrupted, follow the steps below, using the TLJs on the front of the
appropriate DNI-3 panels and two Mini-WECO patch cords (Mini-WECO
plug at each end).
Output
Input
Pos 1
Output
Input
Pos 2
BOR
M
O
I
O
I
M
M
O
I
O
I
M
DNI-3s
1st
Location
2nd
Location